PID GAS DETECTORS – GMI PS500
PID GAS DETECTORS – GMI PS500
The GMI PS500 can be tailored to detect up to five gases with its toxic and catalytic sensors, photo ionisation detectors and infrared capabilities. ‘Plug and Play’ option allows the customer to ‘plug in’ a new board with a different gas range.
The PS500 is particularly useful in noisy environments, featuring a very loud (95dBA) penetrating and distinctive audible alarm together with high visibility large area visual alarm. Pump, diffusion or both together, allowing pumped sample for pre-entry checking and diffusion in confined space working, thus maximising battery life. A robust, moulded, rubberised casing guaranteeing Hi-Impact resistance, the PS500 can be used in the most demanding environments.
A PID sensor is available. This device is suitable for landfill surveying.
KEY FEATURES
- Over 15 plug-and-play smart sensors to choose from
- Wide range of VOC’s with 2 different PID sensors
- Flexible configuration to suit your specification
- Piercing 95 dB audible plus 360-degree high visibility light bar
- On-board datalogging for calibration certificates, data management and event logging
- High impact rubberised case
- IP65
AVAILABLE SENSORS
The following sensors are available for your GMI PS500.
Ammonia (NH3) · Carbon Dioxide (CO2) · Carbon Monoxide (CO) · Chlorine (CL2) · Flammable (LEL) · Hydrogen Sulphide (H2S) · Infra-Red Flammable (IR LEL) · Nitric Oxide (NO) · Nitrogen Dioxide (NO2) · Oxygen (O2) · Phosphine (PH3) · Sulphur Dioxide (SO2) · Volatile Organic Compound (VOC)
DOWNLOAD A BROCHURE
- PS500 Product Brochure (English) (1.99MB)
TECHNICAL SPECIFICATIONS
Measuring Ranges
CO | 0 – 1000ppm | |
O2 | 0-25% | |
CO2 | 0 – 5% VOL | |
Dual Toxic CO / H2S |
0 – 1000ppm (CO) 0 – 100ppm (H2S) |
|
H2S | 0 – 100ppm | |
LEL | 0 – 100% LEL |
**15 plug-and-play smart sensors to choose from (please refer to datasheet)**
Certification
IEC | EEx iad IIC T3/T4 |
ATEX | Ex II 2 G EEx iad IIC T3/T4 |
UL913 | Class I, Div 1, Groups ABCD (excludes NDIR option) |
MED | (0038/YY) – Module B & E |
CE | 0518 |