Please visit www.heathservices.com.au for our new website
Please visit www.heathservices.com.au for our new website

Archive for month: April, 2016

Well Head Lubricant Synthetic Body Filler

PINNACLE #200 … WELL HEAD LUBRICANT BY SEALWELD

well_head_lube

New to Australia, Pinnacle #200 well head lubricant, is suitable for hydraulic fracturing applications that produce extreme operating conditions

Sealweld® Pinnacle #200 is a synthetic well head body filler lubricant that contains special additives to inhibit rust, corrosion and oxidation in side valve body cavities and reduce friction on moving parts.

ECONOMY AND PERFORMANCE …

An economical solution, Pinnacle #200 has excellent resistance to breakdown and washout in drilling fluids, sour gas and other typical drilling by-products.

Well head gate valves take the brunt of the punishment especially when abrasives like sand and rock contact sensitive sealing areas. The excellent adhesive properties of Sealweld® Pinnacle #200 helps protect seat and stem seals from premature breakdown and washout by forming a barrier around these abrasive particles. These properties make Pinnacle #200 well head lubricant suitable for hydraulic fracturing applications that produce very extreme operating conditions.

Use Pinnacle #200 lubricant in well head gate valves, stem seals, gearboxes and bearing assemblies.

well_head_lube_specifications

** Available in 11oz & 15oz cartridges as well as 10lbs & 40lb pails.

Pinnacle #200 well head lubricant is available to purchase in Australia, exclusively through Heath Pipeline Services.

Vehicle Mounted Gas Leak Detection – OMD (Optical Methane Detection) HEATH

OPTICAL METHANE DETECTION – VEHICLE MOUNTED – HEATH OMD

OMD

The Optical Methane Detector (OMD™) was specifi­cally designed for the mobile inspection of buried natural gas distribution, transmission and gathering pipelines

** CLICK HERE TO GET A RECOMMENDATION OR QUOTE FOR ANY HEATH OR GMI GAS DETECTOR **

This field proven technology combines sensitivity, selectivity and speed through the use of optics and electronics.

Field experience has proven that given adequate survey and meteorological conditions the OMD increases productivity 50% or more over current mobile survey.

A contributing factor to the increased productivity is the instantaneous response to leak indications versus the time delay present with cur­rent flame-ionization technologies.

Much of the maintenance associated with flame-ionization units, including moving parts, external fuel gases, outside sources of dust, dirt, moisture and water ingress, is eliminated with the OMD.

Heath_Optical_Methane_Detector_OMD_dashboard

The OMD is mounted on the front of a survey vehicle.

It employs an infrared (IR) light beam that shines across the front of the vehicle. An optical filter in front of the detector transmits methane IR wavelengths from the light source. In the absence of methane, these wavelengths are unaffected and produce a steady output signal from the detector. The presence of methane causes a signal, audio and visual, which is transmitted to the display in analog and digital form inside the vehicle. The OMD can detect leak indications in concentrations of less than 1 part per million (ppm) at 10,000 measurements per second.

OMD-optical-methane-detection

The Heath OMD is calibrated by the driver or technician from inside the vehicle eliminating potential hazards such as explosive calibration gases. Leak indications are both audible and visual inside the vehicle at concentrations of less than 1 part per million (ppm) at 10,000 measurements per second. Data can be sent to a data logger or translated to a ground positioning satellite (GPS) system. Adding-on the Heath Survey Tracker will allow the ability to log mobile leak survey data and GPS locations of all natural gas leaks detected.

** CLICK HERE TO GET A RECOMMENDATION OR QUOTE FOR ANY HEATH OR GMI GAS DETECTOR **

ODOR LEVEL TESTING – HEATH ODORATOR 2

PORTABLE ODOR LEVEL TESTING – HEATH ODORATOR 2

The Odorator 2 is a test instrument designed to evaluate and record odor levels within a utility’s gas stream with respect to actual test locations.  With proper use the Heath Odorator 2,  fulfills D.O.T. Code 192.625 requirements.

Brought to us by Heath USA, the Odorator 2 is suited for use by customer service personnel and other individuals testing odor levels in gas distribution or transmission systems.

odor_level_testing_odorator_2

The Odorator 2 features …

  • One touch zero with flow check
  • Automatic reading correction (linearity, elevation, pressure and temperature)
  • Dual GNSS constellations – GPS and GLONASS
  • Ease of integration with corporate GIS and asset management systems
  • Certified to Class 1, Div 2 for safe use in hazardous locations (pending)
  • Advanced PC software for mapping, report generation and management
  • USB2 and Bluetooth connectivity
  • Rugged design suited to field-work
  • Reliable and easy to use

The Odorator 2 ships with software called OdorSeer.

odorseer_software

** CLICK HERE TO GET A RECOMMENDATION OR QUOTE FOR ANY HEATH OR GMI GAS DETECTOR **

The Heath ODORATOR 2 offers the latest state-of-the-art technology in a handheld, portable, electronic, GNSS based audit system. This instrument is used to evaluate and record the odor levels within a utility’s gas stream with
respect to actual test locations. Natural gas (methane) and propane are two common gases typically odorized and distributed for consumption.

Would you like to learn more …

** CLICK HERE TO GET A RECOMMENDATION OR QUOTE FOR ANY HEATH OR GMI GAS DETECTOR **